RAS/PPP Connection
Important: The modem being used as the RAS/PPP connection must
use the same COM port as the AlarmTraq port you assign for RAS connections. See
below.
Step 1: Click on Edit>System-Wide Options>Misc.

Step 2: Select an AlarmTraq port to be used for RAS connection.
This example uses port 1.
Step 3: Click on the ports tab and make a note of the COM port
number assigned to the AlarmTraq port selected in step 2. In this example Port 1
is using COM3 (see below).

Step 4: Open the Windows Network Connections dialog.

Step 5: Select only the modem assigned to the COM port from step
4. In this example you would select the modem using COM3.
Creating a Windows 2000 Dial-Up Networking Connection
In
order for AlarmTraq to connect to an S8700, S8500 or S8300 system, a dial-up networking
connection must me established.
Step
1: Start the “New Network Connection
Wizard” and select “Dial-up to private network” to create a new connection. Name
this connection ”AlarmTraq” and use the default settings .

Step
2: Right-click on
the new connection named “AlarmTraq” and select “Properties”.

Dial-Up Networking Properties
|

|

|
|
General |
Options |
General:
Select only one modem. The corresponding
AlarmTraq port must be assigned as the RAS port in System Options > Misc >
RAS Port.
|

|

|
|
Security |
Networking |
Security:
Select “Run script” and point
to the “C:\Program Files\AlarmTraq\AlarmTraq.scp”. This file is created each time
AlarmTraq attempts to dial a system configured as RAS/PPP.
Networking:
Select only Internet Protocol
(TCP/IP).
Creating a Windows XP/ Server 2003 Dial-Up Networking
Connection
Step
1: Start the “New
Network Connection Wizard” and select “Dial-up to private network” to create a new
connection. Name this connection ”AlarmTraq” and use the default settings.

Step
2: Right-click on
the new connection named “AlarmTraq” and select “Properties”.